Inter-Worker Governance
Meta-DCC: the same algorithm governing the fleet that governs the search.
14 workers running independently waste compute. On nu3496 (3496 cities), the best worker found 2.02% gap while the worst sat at 4.34% — a 2,212-unit spread representing pure waste. The fix: a Level 1 DCC that monitors all workers, detects fleet stagnation, and (in Phase 2) intervenes by injecting good tours into stuck workers.
Same algorithm at both levels. The Meta-DCC uses the identical LZ76 compression sensor, coupling parameter, and escalation ladder as the base-level worker DCC. The only difference: what the sensor points at. Base-level DCC monitors individual search improvement streams. Meta-DCC monitors fleet-wide state snapshots. Same code. Same math. Different semantics.
The Fleet Lifecycle on uy734 (81 Meta-DCC Steps)
v2.5 ran 14 workers on uy734 (734 cities, optimal 79114) with Meta-DCC monitoring every 30 seconds. The resulting 81-step log revealed a clear three-phase lifecycle:
Steps 1–20
Healthy Fleet
All 14 workers IMPROVING. Fleet best drops rapidly: 83188 → 79942. meta_u climbs 10 → 18 (trust the workers). Spread narrows 1860 → 1342.
Steps 21–55
Stagnation
DEAD workers appear (5–13 per snapshot). Improvements rare. meta_u holds at 18 then starts dropping. Escalation climbs to SHARE level.
Steps 56–81
Fleet Exhaustion
meta_u drops 18 → 3. Step 65: all 14 workers DEAD, zero IMPROVING. Escalation reaches RESTRUCTURE. The sensor says: intervene NOW.
The Self-Calibrating Bands Discovery (P17)
v2.4 hardcoded the LZ compression thresholds at [0.25, 0.65]. Real fleet data lived at [0.01, 0.08] — off by 10×. meta_u drifted to floor and stayed there: useless signal. This was the same mistake as the or-opt exclusion — overriding the system instead of letting it learn.
v2.5 fixed it: self-calibrating bands. The system tracks its own LZ ratio history and derives thresholds from the 25th/75th percentiles of what it has actually observed. After a 10-observation warmup, bands converged to [0.040, 0.061]. meta_u then used its full range [3, 18] with 22 meaningful direction changes. The system that was built to let data decide now lets data decide about its own parameters. MDL all the way down.
Protected section / Zaščiten razdelek
Protected section / Zaščiten razdelek
Result: uy734 reached 0.46% gap (79478) with 14 workers in 40 minutes. Phase 1 is observer-only — workers are identical to v2.3. The value of v2.5 is diagnostic: for the first time, we can see fleet dynamics in real time and have a calibrated sensor for Phase 2 interventions.